No need to vent raditors

Lowers operating costs

Increases energy efficiency in heating and cooling systems

TTM NoXygen® C625

Removes harmful gases in hydronic system

The TTM NoXygen® C625 is part of a series of fully automatic vacuum degassers and easy to install that can be connected for control, regulation and monitoring via Modbus RTU. The unit is designed for permanent operation in apartment buildings for the treatment of fluids in cooling and heating systems up to 25 m3, which corresponds to approximately 200 apartments. A system fluid with a high gas.


Adapted for apartment buildings and smaller systems:

  • Systems up to 25 m3 or about 200 apartments
  • Max system pressure 2.5 bar or about 6 floors height building.

TTM NoXygen® removes free and bound air from the system fluid, increasing the ability to capture and release energy. A system fluid without air provides high thermal comfort, fewer malfunctions, increased lifetime of the heating, cooling or recovery system resulting in reduced operation and maintenance costs.


TTM NoXygen® can be installed in both existing and new systems.


TTM NoXygen® is environmentally assessed.


Installation benefits:

  • Easy to install, commission and control
  • Can be installed in both small and large systems
  • Rapid degassing function


Operation benefits:

  • Reduces operating costs
  • Prevents corrosion of system components
  • No need to vent radiators
  • Increases the energy efficiency of heating
    and cooling systems
  • Minimises noise problems in heating and cooling systems
  • Enables stable and easy adjustment
  • Removes gases from the system fluid
  • Prevents degradation of refrigerant liquids
  • The automation for control, regulation and monitoring is connected via Modbus-RTU.

TTM NoXygen® removes trapped and free gases in heating, heat recovery or cooling systems by lowering the system pressure down to -0.9 bar. Bound gases in the system fluid are released at high pressure and form free gas bubbles, which can then be vented away. Degassing takes place independently of the existing system pressure or media temperature.

 

When TTM NoXygen® is installed for the first time, the device starts automatically in quick degassing mode. This means that the TTM NoXygen® quickly lowers the gas content in the system and then, once the gases have been removed, switches to maintenance degassing.

 

The vacuum degasser is designed for permanent installation to keep the system free of free and bound gases in the long term. When the process is completed, the gas content in the system will gradually increase, as no liquid system is completely diffusion proof. If the system ever needs to be drained of system fluid, the new gas is degassed efficiently through the unit’s quick degassing mode.

 

It takes about 2 weeks to degas 5 m3 of system fluid if the system is previously vented and in good condition. Glycol systems take up to 4 times as long than to degas water. TTM NoXygen® is suitable for system volumes from 0.5 – 25 m3. When the system volume exceeds 25 m3 or where faster degassing is desired, the TTM NoXygen® can be series connected in the return flow of the manifold.

The purpose of fluid treatment by vacuum degassing is to reduce the gas content to a level where corrosion stops and the system fluid regains its optimum energy-carrying properties.

Description: Specification:
Min – Max. system pressure in connection point +0,8 – +2,5 bar
Media temperature 0 – +60°C
Ambient temperature 0 – +40°C
Capacity, degassed liquid Min. 100 l/h
Vacuum capacity during degassing Down to -0,9
Pressure class PN 10
Permitted fluids Water and deionised water – Propylene/ethylene glycol max. 10 vol% Ethanol1 less than 30 vol%
Connection dimension DN15
Electrical data / Voltage 1~230 V, 50 Hz, Plug
Outer fuse 10 A
Rated power 0,5 kW
Rated current 3 A
Energy consumption 25 kWh/year 2
Connection to DUC Modbus RTU (RS485)
Max current load 24 V, 1,0 A
Protection class IP44
Noise level 58 dB
Weight 19 kg
Download CAD file
Article no. 519157
1)When degassing ethanol, ensure the premises are well ventilated. 2) Operation with 30 days of quick degassing results in an energy consumption of 80 kWh the first year.

TTM NoXygen® may be installed in
disturbance sensitiveenvironments such as
hospitals, offices and industries.

Slide

TTM MAG 54

The TTM MAG 54 is an efficient magnetite separator combined with a dirt separator. The unit is primarily intended to be installed together with the TTM NoXygen®.

Slide

TTM MAG 76

The TTM MAG 76 is an efficient magnetite separator combined with a dirt separator. The unit is primarily intended to be installed together with the TTM NoXygen®.

Slide

TTM Offset 600

TTM Offset is a qualisation vessel used with TTM NoXygen in systems that are sensitive to pressure variations.

Slide

TTM Connection hose

The TTM Connection hose is a Butyl hose with stainless steel braiding and internally-threaded connections classified for pressures up to 10 bar.

Slide

Simonsland in Borås

When Kanico created a new district in the town of Borås, they chose TTM to supply shunt units for the HVAC systems. The area is called Simonsland and contains 60,000 m2 of buildings.

Slide

TTM Energiprodukter was one of the suppliers in the construction of the prestigious Copenhagen Opera House Together with their reseller, the company succeeded in winning the deal and delivering 98 different shunt units.

Slide

NCC are building their new head office at Järva Krog in Solna. The new head office has a strategic and easily accessible position adjacent to the E4 motorway.