Space saving design
System divider with heat exchanger
Flexible shunt unit for heating or cooling
Home » Shunt-units » Prefabricated shunt units » TTM shuntopac system dividing shunts » Shuntopac 20-200 UX
System divider shunts for heating or cooling
TTM Shuntopac® UX 20-200 is a system divider for heating or cooling system used where different media, pressures and temperatures in primary and secondary circuits are desired to be hydraulically separated. Specific applications include plants for ground heating.
TTM Shuntopac® UX 20-200 system divider shunt is available with connection dimensions from DN 20 to DN 200 as standard, delivered with each circuit and heat exchanger dimensioned for the current flow.
The shunt unit can be equipped with several components of any make and a number of different coupling alternatives.
The heat exchanger is mounted at the front of the shunt unit which simplifies maintenance. Designed according to the configuration for each shunt unit.
TTM Shuntopac® UX 20-200 is CE marked in accordance with manufacturer’s declaration 2B according to the Machinery Directive.
The shunt unit is environmentally assessed.
Equipment
1. Control valve
Seat valve with flange or threaded connection of any make and type. The valve is fitted into a flanged joint to facilitate maintenance and replacement.
2. Adjusting valves
2 pcs of optional manufacture and dimension.
Fitted to the pipe mixing loop with flange joints TA STAD is delivered as standard. Also available with dynamic balancing valve, flow regulators or difference pressure regulators.
3. Shut-off valves
2 pcs butterfly valves dimensioned to work as end valves if the shunt unit is removed from the system. Mounted in the pipe mixing loop with flange joints.
4. Test sockets
Type TA STAD are attached on each connection.
5. Pump
Optional manufacture and type with “wet” or “dry” motor.
6. Drainage
Design with screwed hose joint R 1/2”.
7. Thermometers
4 pcs graduated 0-120 °C. Mounted in thermowells
6. Heat exchanger
Soldered heat exchanger of any make and type. As standard, the heat exchanger is manufactured by Swep.
Special design
- Pipe mixing loop made of e.g., copper or stainless steel of the desired quality.
Anti-corrosive painted pipe mixing loop, e.g. epoxy enamelled.
Options
- Floor stand
TTM Shuntopac ® 20 -200 UX differential pressure measurement
All outside valves on the TTM Shuntopac® U 20-50 V are provided with test sockets, allowing complete differential pressure measurement.
B – A Measuring of the pressure difference over the adjusting valve on the primary side Primary flow can be determined with the help of data for the adjusting valve.
C – A Available pressure difference on primary side.
G – H Pressure rise over the circulation pump.
H – D Pressure drop in connected object on secondary side.
D – E Measuring of the pressure difference over the adjusting valve on the secondary side.
Secondary flow can be determined with the help of data for the adjusting valve.
E – B Pressure drop over the control valve.
Dimensions TTM Shuntopac® 20-200 UX DN20-50
Connection DN | 20 | 25 | 32 | 40 | 50 |
---|---|---|---|---|---|
A | 750 | 750 | 750 | 750 | 845 |
B | 485 | 485 | 485 | 485 | 610 |
C | 285 + pump | 285 + pump | 285 + pump | 285 + pump | 305 + pump |
D | 200 | 200 | 200 | 200 | 225 |
E | 200 | 200 | 200 | 200 | 240 |
F | 200 | 200 | 200 | 200 | 225 |
G | 67,5 | 67,5 | 67,5 | 67,5 | 70 |
H | 182 | 182 | 182 | 182 | 210 |
I | <175 | <193 | <200 | <205 | <245 |
J | 800 + pump | 800 + pump | 800 + pump | 800 + pump | 1050 + pump |
K | 93 | 93 | 93 | 93 | 112 |
L | Space for actuators, assembly and maintenance. | Space for actuators, assembly and maintenance. | Space for actuators, assembly and maintenance. | Space for actuators, assembly and maintenance. | Space for actuators, assembly and maintenance. |
Weight, approx. kg | 30 | 35 | 50 | 55 | 60 |
Max. pressure: 1,0 MPa
Temp. range: +5 – +110 °C
Specified dimensions are valid for the standard version. Some variations may occur if alternative equipment is used.
Dimensions TTM Shuntopac® 20-200 UX DN65-100
Connection DN | 65 | 80 | 100 |
---|---|---|---|
A | 1150 | 1150 | 1400 |
B | 800 | 800 | 1050 |
C | 300 | 300 | 350 |
D | 125 | 125 | 178 |
E | variabel | variabel | variabel |
F | 290 | 290 | 417 |
G | 995 | 1000 | 1240 |
H | 140 | 140 | 140 |
I | 275 | 275 | 370 |
J | 600 | 600 | 660 |
Weight, approx. kg | 150 | 250 | 350 |
Max. pressure: 1,0 MPa
Temp. range: +5 – +110 °C
Specified dimensions are valid for the standard version. Some variations may occur if alternative equipment is used.
TTM Shuntopac® 20-200 UX
05 VX
06 VX
09 VX
10 VX
TTM SHUNTOPAC® Green Line is a category of shunt units equipped with low-lead valves. Green Line is intended for customers with high demands for improved environmental assessments
TTM SHUNTOPAC® Dynamic gives correct regulation even in systems with varying differential pressures or where the differential pressure is unknown.
TTM SHUNTOPAC® EM is a category of shunt units equipped with ultrasound energy metering equipment according to EN 1434 class 2 and MID 2004/22/EC.
Robust floor stands with small foot-print made of epoxy-coated RHS tubes 50 × 30 mm.
Simonsland in Borås
When Kanico created a new district in the town of Borås, they chose TTM to supply shunt units for the HVAC systems. The area is called Simonsland and contains 60,000 m2 of buildings.
TTM Energiprodukter was one of the suppliers in the construction of the prestigious Copenhagen Opera House Together with their reseller, the company succeeded in winning the deal and delivering 98 different shunt units.
NCC are building their new head office at Järva Krog in Solna. The new head office has a strategic and easily accessible position adjacent to the E4 motorway.